On Mon, Oct 01, 2018, Seibold, Steve Allan wrote:
>
> I am trying to obtain the water density after my minimization (NPT)
> steps to verify that I have the proper density but I cannot find it in
> the log print out or how to obtain it using some module in AMBER..Is
> there an straightforward way to obtain this info? I looked online but I
> could not find the answer..
Only molecular dynamics "knows about" pressure, since it is only with dynamics
that one has kinetic energy that is a key ingredient in computing the
pressure. Minimization never changes the box size, and is not NPT. Hence,
you won't find any such information in a minimization run. The density will
be unchanged from the initial value. (You can use "summary" command in parmed
to compute the density of the system.)
...good luck....dac
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber