> Hi Chitrak,
You are reading that reply incorrectly. It says "No, the force fields should be compatible". To clarify. Lipid 14 is full compatible with FF14SB. It was designed that way from the beginning and there is nothing special you need to do to use them both together.
All the best
Ross
> On Nov 29, 2017, at 1:05 PM, Chitrak Gupta <chgupta.mix.wvu.edu> wrote:
>
> Hello,
>
> I recently came across this post
>
> http://archive.ambermd.org/201506/0131.html
>
>
> Just wanted to clarify: Is lipid 14 not compatible with FF14SB? If not,
> which protein force field should I use with lipid 14?
>
>
> Also, are each one compatible with the OPC water model?
>
>
> Best regards,
> Chitrak.
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Nov 29 2017 - 12:00:02 PST