Hi David,
Thanks for the advice last week. I was not aware of the difference in LJ parameter units in AMBER.
When checking the validity of a dry prmtop in parmed.py it says *.prmtop looks OK to me! The TIP3P waters are thus to blame.
My system contains a water coordinated to ZN. When printing the LJ types I noticed that the oxygen of the active site water is type index 20 whereas all the other TIP3p OW atoms are LJ type index 23. In parmed I can set the radius and well depth to new values but these are equivalent for type 20 and 23.
Is there any way to change the type index from 20 to 23?
The water behaviour during minimization is suspect and I just want to confirm that this is not the cause.
Kind regards
Lizelle Lubbe
PhD (Medical biochemistry) candidate
Department of Integrative Biomedical Sciences
University of Cape Town
________________________________________
From: David A Case <david.case.rutgers.edu>
Sent: 25 August 2017 10:17:08 PM
To: AMBER Mailing List
Subject: Re: [AMBER] TIP3p lennard jones parameters
On Fri, Aug 25, 2017, Lizelle Lubbe wrote:
> I noticed that the TIP3P parameters in this file do not correspond to
> the literature (radius 3.15061; well depth 0.6364)
> My values are 1.7683 and 0.1520 respectively.
Your "literature" values are sigma (in Å) and epsilon (in kJ/mol). Amber
uses Rmin/2 (in Å) and epsilon in kcal/mol. If you convert to what
Amber uses, you will find that they match.
>
> If not, how can I increase the verbosity in parmed.py to come to the
> bottom of this?
I agree that there are situations where it would be quite helpful if
parmed could print more information when it finds problems. Volunteers
are hereby solicited.
>
>
> source leaprc.ff14SB
General advice: upgrade to AmberTools17. Second, if you think that your
water model might be leading to off-diagonal LJ parms, do some exploring:
make a prmtop with just water (for example), and see what parmed says. Keep
adding in components one by one to see if you can isolate the problem.
...good luck....dac
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Disclaimer - University of Cape Town This e-mail is subject to UCT policies and e-mail disclaimer published on our website at
http://www.uct.ac.za/about/policies/emaildisclaimer/ or obtainable from +27 21 650 9111. If this e-mail is not related to the business of UCT, it is sent by the sender in an individual capacity. Please report security incidents or abuse via csirt.uct.ac.za
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Thu Aug 31 2017 - 02:00:02 PDT