Re: [AMBER] weird asymmetries in solvent box

From: Thomas Pochapsky <pochapsk.brandeis.edu>
Date: Wed, 19 Apr 2017 15:03:18 -0400

Thanks, dac, that fixed the problem. Tom


On 4/17/17 10:32 AM, David Case wrote:
> On Mon, Apr 17, 2017, Thomas Pochapsky wrote:
>
>> Thanks, Dave. I'll try those. Does the periodic box size get reset
>> automatically to maintain uniform solvent density?
> It gets reset to match the given external pressure (generally 1 atm by
> default). It doesn't care if the solvent density is uniform on not: in fact,
> in the vicinity of a protein, the solvent density will be markedly
> non-uniform.
>
> ....dac
>
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber


_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Apr 19 2017 - 12:30:02 PDT