Re: [AMBER] pbsa EDISPER with radiopt=0 vs radiopt=1

From: Ray Luo <rluo.uci.edu>
Date: Fri, 24 Feb 2017 08:35:37 -0800

Hi Paulo,

Thanks a lot for pointing this out! We'll do a similar test to see
where the potential issue is located.

All the best,
Ray
--
Ray Luo, Ph.D.
Professor of Structural Biology/Biochemistry/Biophysics,
Chemical Physics, Biomedical Engineering, and Chemical Engineering
Department of Molecular Biology and Biochemistry
University of California, Irvine, CA 92697-3900
On Fri, Feb 24, 2017 at 1:32 AM, Paulo Costa <pjfmcosta.gmail.com> wrote:
> Dear AMBER users
>
> I'm sorry for the long post ...
>
> I'm performing some test calculations with the pbsa solver (AmberTools16)
> to get the solvation free energies of small molecules. These small
> molecules are built with antechamber using GAFF atom types.
>
> I started with a simple single point calculation using the example from the
> manual
>
> Sample single point PB calculation
> &cntrl
> /
> inp=2
> &pb
> npbverb=1, istrng=150, fillratio=1.5, saopt=1, radiopt=1
> /
>
> I got the non-polar contribution modeled by 2 terms, cavity + dispersion
> (inp=2) and I since GAFF atom types are employed, radii from the prmtop
> file will be used according to the manual (radipot=1). This calculation
> yielded
>
> EPB = -12.3409 | ECAVITY= 16.4597  | EDISPER = -15.1553
>
> So, let's imagine I want to optimize the radii of the elements of my
> molecule. The manual states that one should change the RADII section of the
> topology and read those radii via RADIOPT=0. But if I use the exact same
> topology as before, the radii should be the same. Therefore, I repeated the
> calculation with
>
> Sample single point PB calculation
> &cntrl
> /
> inp=2
> &pb
> npbverb=1, istrng=150, fillratio=1.5, saopt=1, radiopt=0
> /
>
> and I got
>
> EPB = -12.3409, ECAVITY= 16.4597, EDISPER = -17.0143
>
> the value for EDISPER is completely different. Using the verbose option in
> both runs, I confirmed in the output that all radii (PB and NP) are exactly
> the same for both runs.
>
> Besides EDISPER, the outputs differ in the following
>
> <    Use Tan, Yang, and Luo optimized cavity radii definition
> ---
>>    Use cavity radii in the prmtop file
>
> Indeed, if one changes the RADII section in the topology for one or more
> atoms, this only affects the EPB values as these are used for for the
> electrostatic contribution calculation. Apparently the NP radii are always
> the Rmin values of the FF. If so, it makes sense that the ECAVITY term is
> equal regardless if we use radiopt = 0 or 1 since, in both cases, Rmin
> values are used. On the other hand, why are EDISPER values different?
>
> If we optimize a radii for an element (via the topology), we should run a
> radiopt = 0 but how to compare it with the non-optimized raddii? The
> default calculations are performed with radiopt = 1 but that will change te
> contribution from EDISPER as well ...
>
> If one wishes to optimize the NP radii, used for the calculation of the
> non-polar contributions, we have to "hack" the source code? Or is there any
> other way to do it (e.g. via topology)?
>
> Again, sorry for the long post and thanks in advance for your help!
>
> Paulo Costa
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Fri Feb 24 2017 - 09:00:03 PST