On Wed, Feb 08, 2017, Andreas Gavrielides wrote:
>
> I would like a clarification in regard to the pairwise parameters used
> in GAFF. For the sigma (σ) values needed to calculate the LJ potential
> is it sufficient to just divide by 2^(1/6) or is it also mandatory to
> multiply by 2. Because if not multiplied by 2 the sigma parameters are
> too small and almost two times smaller than those in other AMBER force
> fields.
The values in the nonbonded lines of a parm.dat file are Rmin/2 and epsilon.
Rmin/2 is in Angstroms, epsilon is is kcal/mol
Rmin/2 = sigma*(2**1/6)/2 where "sigma" is a standard LJ sigma parameter.
This has nothing to do with gaff or gaff2: all Amber parameter files use
this format.
More info is here: http://ambermd.org/Questions/vdwequation.pdf
...hope this helps....dac
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Feb 08 2017 - 10:30:03 PST