Re: [AMBER] VdW parameters in AMBER

From: David Case <david.case.rutgers.edu>
Date: Wed, 8 Feb 2017 13:28:42 -0500

On Wed, Feb 08, 2017, Andreas Gavrielides wrote:
>
> I would like a clarification in regard to the pairwise parameters used
> in GAFF. For the sigma (σ) values needed to calculate the LJ potential
> is it sufficient to just divide by 2^(1/6) or is it also mandatory to
> multiply by 2. Because if not multiplied by 2 the sigma parameters are
> too small and almost two times smaller than those in other AMBER force
> fields.

The values in the nonbonded lines of a parm.dat file are Rmin/2 and epsilon.
Rmin/2 is in Angstroms, epsilon is is kcal/mol

Rmin/2 = sigma*(2**1/6)/2 where "sigma" is a standard LJ sigma parameter.

This has nothing to do with gaff or gaff2: all Amber parameter files use
this format.

More info is here: http://ambermd.org/Questions/vdwequation.pdf

...hope this helps....dac