[AMBER] distance restraints failed

From: Qinghua Liao <scorpio.liao.gmail.com>
Date: Wed, 25 Jan 2017 16:44:55 +0100

Hello,

I am doing umbrella sampling with amber16, the reaction coordinates are
the distances
between a metal ion and an oxygen of a water molecule. But I found that
the distance restraints
were failed for some windows. Here are my input files:

  &cntrl
    imin = 0, nstlim = 25000, irest = 0, ntx = 1, dt = 0.002 ,
    ntt = 3, temp0 = 300.0, gamma_ln = 2.0, ig = -1,
    ntp = 1, pres0 = 1.0, taup = 2.0,
    ntb = 2, cut = 12.0 ,
    ntc = 2, ntf = 1,
    iwrap = 1, nmropt = 1 ,
    ntwe = 5000, ntwx = 5000, ntpr = 5000, ntwr = 5000,
  /
&wt
   type='DUMPFREQ', istep1=50, /
  &wt
   type='END',
  &end
DISANG=restraints.dat
DUMPAVE=distance.dat


Harmonic restraints for distance of 1.6 angstrom
  &rst
   iat=345,425,
   r1=0, r2= 1.6, r3= 1.6, r4=5.0,
   rk2= 500.0 , rk3= 500.0 ,
  &end

What I got for the distances from the simulation are around 2.0
angstrom, it never approaches 1.6 angstrom.
I even tried with a much higher force constant like 1000 kcal/mol A2,
then the distances go to around 1.9 angstrom,
but still not 1.6. However, the restraints are working for those windows
with restrained distances more than 2 angstrom.

Then I also try to restrain a distance between two water molecules at a
distance of 1.6, the restraints was also failed.
Similarly, it worked if I want to restrain the distance at 3.0 angstrom.

This is strange to me. Though we may think that the interaction between
a water molecule and the metal ion could be very
strong, a force constant of 500 or even 1000 kcal/mol A2 should make it
work. Could someone help me out of the problem?
Any response will be highly appreciated!


All the best,
Qinghua




_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Jan 25 2017 - 08:00:02 PST