Hi,
My system consists of a protein-ligand complex with few co-crystallized
waters and I am trying to add ions to this system.
I am using AmberTool16. First I solvated my system and next when I tried
1) addIonsRand: I found that ions were random distributed but some of the
ions were within my protein. Therefore, I can not use such system.
2) addions2: I found that all ions were outside the water box and were
arranged in one plane. I understand that "addions2" considers solute and
solvent both and therefore added ions were outside the box.
3) addions: This time I found that ions were within the solvent box and
were not inside the protein. But, the ions are still not uniformly
distributed (see attached figure). I am afraid if it may affect my
simulation.
*Thanks,Hirdesh*
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Dec 20 2016 - 10:30:03 PST