[AMBER] Potential energy fluctuation of NVT ensemble

From: Zhe Li <zheli.Dal.Ca>
Date: Fri, 4 Nov 2016 01:45:22 +0000

Dear all,

I ran a production NVT simulation and found that the fluctuation of potential energy is as large as several hundreds kcal/mol. Is this kind of fluctuation normal? At first I thought this was because the geometry of the frames was not optimized. But after I used Sander to optimize some of the frames with ntmin = 3, the large energy difference was still there. I visualized the trajectory. It seems that this potential energy difference is caused by change of conformations. My calculation is on a metalloenzyme after initial equilibration including constrained minimization, full minimization, and warming up by a short NPT. The input files are attached. If my result is unusual, is there something wrong with my input files? Thank you.

Zhe Li


Input files:

min1.in
Initial minimization solvent + ions
&cntrl
 imin = 1,
 maxcyc = 5000,
 ncyc = 2500,
 ntb = 1,
 igb = 0,
 ntr = 1,
 cut = 8.0
/
Hold the substrate fixed
500.0
RES 1 464
END
END

min2.in
 &cntrl
 imin = 1,
 maxcyc = 50000,
 ncyc = 25000,
 ntb = 1,
 igb = 0,
 ntr = 0,
 cut = 8.0
/

eq.in
100ps MD with res
&cntrl
 imin = 0,
 irest = 0,
 ntx = 1,
 ntb = 2, ntp = 1,
 pres0 = 1.0, taup = 2.0
 cut = 8.0,
 ntr = 1,
 ntc = 2,
 ntf = 2,
 tempi = 0.0,
 temp0 = 300.0,
 ntt = 2, ig = -1,
 nstlim = 50000, dt = 0.002,
 ntpr = 1000, ntwx = 2000, ntwr = 2000,
/
Keep substrate fixed with weak restraints
10.0
RES 1 464
END
END

md.in
100 ns MD
&cntrl
 imin = 0, irest = 1, ntx = 7,
 ntb = 1,
 cut = 8.0, ntr = 0,
 ntc = 2, ntf = 2,
 tempi = 300.0, temp0 = 300.0,
 ntt = 3, gamma_ln = 1.0,
 nstlim = 50000000, dt = 0.002,
 ntpr = 10000, ntwx = 10000, ntwr = 10000
 ioutfm = 1,
 iwrap = 1,
 ig = -1,
/