Re: [AMBER] QM/MM MD with Amber-Gaussian interface

From: Dr. Andreas W. Goetz <agoetz.sdsc.edu>
Date: Thu, 13 Oct 2016 12:55:59 -0700

Dear Monsurat,

As the error message indicates, the QM calculation with Gaussian failed. Did you run the test suite? Do the QM/MM tests for Gaussian pass?

There should be a log file called gau_job.log that contains the output from the Gaussian run. Have a look at this file, it should provide information why the job failed (e.g. SCF did not converge etc). Your job could fail for a variety of reasons, for instance SCF failure is not uncommon if the structure in your QM region is very distorted.

All the best,
Andy

Dr. Andreas W. Goetz
Assistant Project Scientist
San Diego Supercomputer Center
Tel: +1-858-822-4771
Email: agoetz.sdsc.edu
Web: www.awgoetz.de

> On Oct 13, 2016, at 12:41 PM, Monsurat Lawal <lawalmonsurat635.gmail.com> wrote:
>
> Dear Subscribers,
>
> I am having a challenge with running QM/MM calculations interfacing Amber
> with Gaussian09.
>
> This error kept popping up:
>
> SANDER BOMB in subroutine get_gau_forces (qm2_extern_gau_module)
> Error with system call (executing Gaussian)
> Will quit now.
>
> My input file looks like:
> Example QM/MM input for Sander-12 - Gaussian interface
> &cntrl
> imin=1,
> maxcyc=10,
> ntb=1,
> cut=20,
> ifqnt=1
> /
> &qmmm
> qmmask='.1558-1576,5576-5597,7914-7967',
> qmcharge=0,
> spin=1,
> qm_theory='EXTERN',
> qm_ewald=0,
> qmcut=20,
> /
> &gau
> method = 'B3LYP',
> basis = '6-31G',
> /
>
> Looking forward to cool solution(s).
>
> Regards,
> Monsurat.
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber