Re: [AMBER] Problem regarding sccdftb not converging

From: Thakur, Abhishek <axt651.miami.edu>
Date: Fri, 30 Sep 2016 16:07:04 +0000

Hi Amitosh


What you can do is try using

dftb_telec= 100K and gradually increase it if still there is convergence problem.

Electronic temperature, in K, used to accelerate SCC convergence in DFTB calculations. The elec- tronic temperature affects the Fermi distribution promoting some HOMO/LUMO mixing, which can accelerate the convergence in difficult cases. In most cases, a low telec (around 100K) is enough. Should be used only when necessary, and the results checked carefully. Default: 0.0K


Along with this you can also increase the number of cycles and see if helps in convergence.


With regards,

Abhishek


________________________________
From: amitosh gautam <amitosh.gautam.students.iiserpune.ac.in>
Sent: Thursday, September 29, 2016 6:36:34 PM
To: amber.ambermd.org
Subject: [AMBER] Problem regarding sccdftb not converging

Hello,

I am doing sccdftb calculations in AMBER 12 . Atomtypes which are being
used in the calculations are C, H, N, O, P, MG. During the calculations I
am getting "sccdftb not coverging" error. This error is being removed when
I am using only C, H, N, O but calculations with any of P or MG I am
getting the same error.

Please let me know how should I solve the error.

Thanks

Regards,

Amitosh Gautam
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
https://urldefense.proofpoint.com/v2/url?u=http-3A__lists.ambermd.org_mailman_listinfo_amber&d=DQICAg&c=y2w-uYmhgFWijp_IQN0DhA&r=0Hah93XWYYBgmROOVcaccg&m=jeXAJq2jZg9ZQqZ0mXec1FSy01DxGGGvCv4CrM5rNPE&s=AowZr0A_uXELdP8sc1QWUbupsCEk-zTGQpPcD3t4FEU&e=
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Fri Sep 30 2016 - 09:30:02 PDT