Hi
I have a question that if I don't mention 0,1 or 2 then by default amber will consider which model?
Thanking you,
AT
________________________________
From: Ray Luo <rluo.uci.edu>
Sent: Monday, August 1, 2016 6:35:04 AM
To: AMBER Mailing List
Subject: Re: [AMBER] default value (inp= 0,1,2)? MMPBSA
AT,
INP=0 turns off nonpolar solvation model; INP=1 is the classical model
that uses a single surface tension to correlate with the nonpolar
solvation free energy; and INP=2 is the modern model that uses two
terms to correlate with dispersion and hydrophobic terms separately.
See
Tan, et al, The Journal of Physical Chemistry B 111 (42), 12263-12274, 2007
All the best,
Ray
--
Ray Luo, Ph.D.
Professor
Biochemistry, Molecular Biophysics, Chemical Physics,
Chemical and Biomedical Engineering
University of California, Irvine, CA 92697-3900
On Mon, Aug 1, 2016 at 9:35 AM, Thakur, Abhishek <axt651.miami.edu> wrote:
> Hi
>
> I am doing MMPBSA calculation,
>
> I would like to know for inp = 0,1,2 what is the default value in amber.
>
> As I can understand all are 3 different model, but curious to know what is the default model.
>
>
>
> Thanking you,
>
> AT
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> https://urldefense.proofpoint.com/v2/url?u=http-3A__lists.ambermd.org_mailman_listinfo_amber&d=CwICAg&c=y2w-uYmhgFWijp_IQN0DhA&r=0Hah93XWYYBgmROOVcaccg&m=0oMQK4VKsuqEgXz-aDvcLMCdowlw0AuSqDydTdg3TK8&s=LYtK5XPmz7lVgVmCT20npgcOflpfcMpD352Ij6cyzuU&e=
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
https://urldefense.proofpoint.com/v2/url?u=http-3A__lists.ambermd.org_mailman_listinfo_amber&d=CwICAg&c=y2w-uYmhgFWijp_IQN0DhA&r=0Hah93XWYYBgmROOVcaccg&m=0oMQK4VKsuqEgXz-aDvcLMCdowlw0AuSqDydTdg3TK8&s=LYtK5XPmz7lVgVmCT20npgcOflpfcMpD352Ij6cyzuU&e=
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Mon Aug 01 2016 - 12:00:02 PDT