Re: [AMBER] Scripts to gradually remove NMR restraints during MD simulation

From: ankita mehta <mehtaroadies.gmail.com>
Date: Fri, 13 May 2016 15:32:48 +0530

Dear ,
In the following
&wt type='REST', istep1=1,istep2=300000,value1=1.0,value2=1.0, /
&wt type='END' /

You can change the value of istep1 and istep 2 to a particlar step at which
a particular value of the Rstraint is needed and which is defined through
the weights in value 1 and value 2 .
Subsequently , you can add many lines which will have varying istep 1 and
istep 2 and value 1 and value 2 .
Thanks!

On Fri, May 13, 2016 at 3:16 PM, Vasantha Kumar <vin.vasanth.gmail.com>
wrote:

> Dear AMBER users
>
> Does any have script (links) to gradually remove NMR restraints during MD
> simulation.
>
> thanks in advance
>
> Vince
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Fri May 13 2016 - 03:30:04 PDT