On Mon, Jan 25, 2016 at 1:23 PM, Lara rajam <lara.4884.gmail.com> wrote:
> Dear Amber
>
> I would like to bring the ligand from far distance from the receptor to the
> surface of the receptor. The atoms that I have selected on the ligand and
> on the receptors are now 22.5 angstrom apart. I need to pull the ligand to
> near the surface of the receptor, which is 16.2 angstrom from the receptor
> fixed atom. I have used the following parameters to run the simulation. I
> have enclosed restrain file too. In restrain for these kind of simulation
> the ifvari=1 should be applied. When I see the distance change between the
> two points it is not linear it jumps randomly. How I can control the
> variables to make the force so that the distance decrease with respect to
> time is linear.
>
It sounds like you are trying to do "steered" molecular dynamics. You can
find an example of a steered MD simulation in $AMBERHOME/test/jar. I would
also recommend reviewing some literature to see how this type of study has
been performed in the past (in my experience, two species are usually
pulled *apart* rather than *together* due to the decrease in entropy
associated with binding events.
HTH,
Jason
--
Jason M. Swails
BioMaPS,
Rutgers University
Postdoctoral Researcher
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Jan 26 2016 - 05:00:03 PST