[AMBER] g03 error message

From: Damiano Spadoni <enxds6.nottingham.ac.uk>
Date: Sun, 24 Jan 2016 18:15:49 +0000

Dear Ambers,

I am try to run an optimisation step on Gaussian03 of an adduct of pyridoxalphosphate - lysine and it stopped with the following message:

No NMR shielding tensors so no spin-rotation constants.
 Leave Link 601 at Sat Jan 23 12:07:12 2016, MaxMem= 134217728 cpu: 8.4
 (Enter /cm/shared/apps/gaussian/g03/l9999.exe)


 THERE IS MORE TO LIFE THAN INCREASING ITS SPEED.

                                       -- GANDHI
 Error termination request processed by link 9999.

I've read on previous Amber queries that might be a Gaussian bug, but on its manual the NMR - tension bug has been fixed.

Does anyone has encountered this message before?

This is the input file I used:

%chk=PLP_19Jan_chk
%mem=1GB
%nprocshared=16
#P B3LYP/6-31G* Opt

PLP_19Jan

-2 2
N -24.28154 -2.89752 -17.88587
C -25.18240 -1.95617 -17.23281
C -26.01386 -2.74614 -16.19640
O -26.60759 -3.89180 -16.71814
C -26.06782 -1.23575 -18.29111
C -27.00036 -2.14696 -19.10504
C -27.76486 -1.33194 -20.15314
C -28.78356 -2.19763 -20.90029
N -29.50274 -1.41350 -21.90156
O -26.96750 -1.94842 -15.55286
N -21.14225 -6.19832 -20.10462
C -22.49462 -6.34003 -19.65720
C -23.10231 -7.70644 -19.76153
C -23.14872 -5.25842 -19.17893
O -24.44631 -5.39042 -18.75864
C -22.46940 -3.91567 -19.14018
C -23.20606 -2.72819 -18.58921
C -21.19319 -3.83374 -19.60057
C -20.51883 -5.06778 -20.08955
C -20.37250 -2.57074 -19.64908
O -20.92137 -1.70564 -20.60682
P -19.75516 -0.44714 -20.95461
O -19.83286 0.83394 -19.79060
O -20.15762 0.16718 -22.31882
O -18.13038 -1.04465 -21.14353
C -24.40606 -0.92290 -16.43119
O -24.68402 0.41875 -16.53949
O -23.57485 -1.28031 -15.61583
H -25.38913 -0.70201 -18.99782
H -26.70344 -0.47698 -17.79064
H -27.74418 -2.61269 -18.42298
H -26.41797 -2.94271 -19.61158
H -27.04006 -0.89398 -20.87851
H -28.31072 -0.50053 -19.65086
H -29.51398 -2.61906 -20.17010
H -28.26216 -3.04519 -21.40155
H -28.83624 -1.05133 -22.61872
H -29.99778 -0.61034 -21.44424
H -30.20929 -2.02048 -22.37047
H -22.50644 -8.42210 -19.16233
H -23.09313 -8.03232 -20.82659
H -24.15159 -7.73729 -19.39981
H -24.99868 -5.04082 -19.50770
H -22.81385 -1.72309 -18.70896
H -19.49947 -5.04346 -20.44874
H -19.32492 -2.84080 -19.92095
H -20.34707 -2.09485 -18.64372

Many thanks,

Damiano Spadoni




This message and any attachment are intended solely for the addressee
and may contain confidential information. If you have received this
message in error, please send it back to me, and immediately delete it.

Please do not use, copy or disclose the information contained in this
message or in any attachment. Any views or opinions expressed by the
author of this email do not necessarily reflect the views of the
University of Nottingham.

This message has been checked for viruses but the contents of an
attachment may still contain software viruses which could damage your
computer system, you are advised to perform your own checks. Email
communications with the University of Nottingham may be monitored as
permitted by UK legislation.

_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Sun Jan 24 2016 - 10:30:02 PST
Custom Search