On Thu, Jul 16, 2015, Asmita Gupta wrote:
>
> I have some basic questions regarding running SGLD simulation in amber14.
>
>
> The total no of atoms in my system are 359214 (including waters), but i am
> printing only 1-864 atoms in the trajec file..However, a run of 1ns takes
> approx 72-75 hrs to finish. (40 xeon cores , E52680)
Which program are you using? How many nodes do you have, and what is the
nature of the interconnect between nodes?
>
> 1.) In explicit solvent conditions, does the guiding force is limited to
> only solute or is applied to solvent molecules also? Is this why 1ns run is
> taking this much time?
SGLD is probably not the culprit here. You can easily compare timings for a
short run with and without SGLD to compare timings.
>
> 2.) Can i use something like isgsta=1 and isgend=864 to specify the range
> on which guiding force should be applied?
You can try this. I doubt that it will affect the timings, but you can easily
enough experiment to find out. I'd suggest trying some test simulations with
many fewer waters, to get a feeling for what is affecting your performance.
Don't forget to try fewer cores as well.
...dac
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Thu Jul 16 2015 - 06:00:05 PDT