Dear Friends,
I am running pmemd.cuda.MPI (AMBER14) in Tesla K40s gpu cards for an
explicit water DNA system with SPFP precision model. After running few
steps sucessfully, I am getting **** for temperature and energy values as
typed below followed by the md input file.
 NSTEP =    45000   TIME(PS) =   54230.000  TEMP(K) =   300.15  PRESS =
0.0
 Etot   =  -1102980.4479  EKtot   =    216143.9219  EPtot      =
-1319124.3698
 BOND   =      8297.0959  ANGLE   =     17306.9385  DIHED      =
22929.3885
 1-4 NB =      8627.8031  1-4 EEL =    -71177.7576  VDWAALS    =
134764.0741
 EELEC  =  -1439871.9123  EHBOND  =         0.0000  RESTRAINT  =
0.0000
 ------------------------------------------------------------------------------
check COM velocity, temp:             NaN      NaN(Removed)
 NSTEP =    50000   TIME(PS) =   54240.000  TEMP(K) =      NaN  PRESS =
0.0
 Etot   =            NaN  EKtot   =            NaN  EPtot      =
**************
 BOND   =         0.0000  ANGLE   =   4770613.6638  DIHED      =
0.0000
 1-4 NB = **************  1-4 EEL = **************  VDWAALS    =
**************
 EELEC  = **************  EHBOND  =         0.0000  RESTRAINT  =
0.0000
 ------------------------------------------------------------------------------
Here is my md input file
Production run  with constant volume
 &cntrl
  ntx=6,        irest=1,
  nmropt=0,
  ntrx=1,       ntxo = 2,
  ntpr=5000,    ntwx=5000,      ntwr=10000,
  ntwv=0,
  ntf=2,        ntb=1,
  cut=9.0,      nsnb=10,
  nstlim=1000000,       nscm=10000,
  t=0.0,        dt=0.002,
  ntt=1,        tautp=0.5
  ntp=0,        pres0=1.0,      taup=0.5,       comp=44.6
  tempi=300.0,  temp0=300.0,
  ipol=0,       ntc=2,  ioutfm  = 1
 /
 &ewald
 /
Though, I am running another NPT run using Langevin dynamics using
anisotropic pressure coupling and MC barostate with same pmemd.cuda.MPI and
it is running fine.
Is it something known problem or I am missing something, please comment.
Thanks in advance for your valuable time.
*With Regards,HIMANSHU JOSHI Graduate Scholar, Center for Condense Matter
TheoryDepartment of Physics IISc.,Bangalore India 560012*
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue Mar 31 2015 - 11:00:02 PDT