On Tue, Mar 17, 2015, Anasuya Dighe wrote:
> 
> 
> command used :  antechamber -i pepstatin_new.pdb -fi pdb -o pepstatin_new.mol2
> -fo mol2 -c bcc -s 2
> 
>  Running: /home/amber/amber14/bin/sqm -O -i sqm.in -o sqm.out
>  Error: cannot run "/opt/apps/amber/amber12/bin/sqm -O -i sqm.in -o sqm.out" of
> bcc() in charge.c properly, exit
> 
>  Here is the end of the output file of sqm.out
>  --------------------------------------------------------
>  QMMM: System specified with odd number of electrons ( 215)
>  QMMM: but odd spin ( 1). You most likely have the charge of
>  QMMM: QM region (qmcharge) set incorrectly. Correct error and re-run
>  calculation.
To add to what was said before: this issue probably arises because pepstatin
is a charged molecule.  The antechamber default is for zero charge, and you
must use the "-nc" flag to change that.
....dac