On Thu, 9 Oct 2014 07:25:52 -0500
David A Case <case.biomaps.rutgers.edu> wrote:
> On Thu, Oct 09, 2014, Hannes Loeffler wrote:
> >
> > sander(14) claims in some of my simulations that the common atoms
> > do not have the same coordinates. As these are the final
> > coordinates of a simulation I had a closer look and found that one
> > state got imaged while the other one was on the other side of the
> > box (distance between common atoms exactly the same lengths as one
> > of the box dimensions). Maybe the code doesn't make sure that
> > imaging is done in sync? I should probably add that I am running
> > tests on small molecules and traversing of periodic boundaries is
> > thus quite frequent.
>
> Can you set iwrap=0 and ntxo=2? That avoids wrapping, which will
> almost certainly cause problems in TI, and also removes the size
> restriction on the coordinates in the restart file.
Many thanks. That's a good option.
--
Scanned by iCritical.