Re: [AMBER] MMPBSA

From: Jason Swails <jason.swails.gmail.com>
Date: Thu, 18 Sep 2014 07:37:07 -0400

On Thu, 2014-09-18 at 13:30 +0530, Sourav Purohit wrote:
> While peforming entropy calculation using MMPBSA.py, I get the message:
>
> Line minimizer aborted: step at upper bound 0.074487672
> Line minimizer aborted: step at upper bound 0.00086134154
> Line minimizer aborted: step at upper bound 0.0014747638
> Line minimizer aborted: step at upper bound 0.012288468
> Line minimizer aborted: step at upper bound 0.055832154
> Line minimizer aborted: step at upper bound 0.00056890766
> Line minimizer aborted: step at upper bound 7.3399234e-05
> Line minimizer aborted: step at upper bound 0.096555206
> Line minimizer aborted: step at upper bound 0.0012406
>
> and this continues.
> What should be done to get rid of this??

This indicates that the minimizer is having a hard time finding a local
minimum. There's not much you can do about it short of finding another
way to minimize your structures before feeding it to MMPBSA.py. If a
minimum cannot be found, that snapshot will likely be skipped when doing
the normal mode calculations.

HTH,
Jason

-- 
Jason M. Swails
BioMaPS,
Rutgers University
Postdoctoral Researcher