Re: [AMBER] NMR distance restrains

From: David A Case <case.biomaps.rutgers.edu>
Date: Wed, 2 Jul 2014 10:14:29 -0400

On Wed, Jul 02, 2014, Valentina Romano wrote:

> #
> # 83 GLU O 247 D6A N6 4.0
> &rst
> ixpk= 0, nxpk= 0, iat=1273,3839, r1= 1.30, r2= 1.80, r3= 4.00, r4= 4.50,
> rk2=20.0, rk3=20.0, ir6=1, ialtd=0,
> &end

As long as the distance between atoms 1273 and 3839 is between r2 and r3 (i.e.
between 1.8 and 4.0 angstroms) you will have a zero restraint energy. I
suspect that this is what you are seeing.

> Number of restraints read = 2

This indicates that your restraints were read in. To get more debugging
output, add a LISTIN=POUT line in the restraint section. That will give
you detailed info about all the restraints that are being used.

...good luck....dac


_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Jul 02 2014 - 07:30:04 PDT