Re: [AMBER] cpptraj grid function

From: Daniel Roe <daniel.r.roe.gmail.com>
Date: Sat, 22 Mar 2014 16:01:12 -0600

Hi,

Without knowing exactly what your trajectory looks like it's tough to make
an exact diagnosis, but I suspect there may be an issue as to where the
grid is centered. In your second step try centering your solute at the
origin after the origin command, then try to create the grid (no need for a
step 3) placing the center of your grid at the origin as well, e.g.:

...
rms reference mass :1-388
center :1-388 origin
grid wat_grid.xplor 60 2 60 2 100 2 :WAT.O origin
trajout test_princi_rms.nc nc
run ### STEP2

Hope this helps,

-Dan



On Sat, Mar 22, 2014 at 12:43 PM, Jio M <jiomm.yahoo.com> wrote:

> Dear All
>
> I have a long polymer around 100 Angs length and 60 Angs diameter with 388
> resdiues and in octahedron water/ions box. I want to calculate spatial
> distribution of water along the length using grid option (following some
> archive mail: http://archive.ambermd.org/201109/0613.html)
>
> So I have run following cpptraj commands for just 10 frames for test:
> (first two runs are for aligning along Z which works fine and was kindly
> suggested by Daniel few weeks before; final third run is for grids):
>
>
> trajin initial.inpcrd
> principal :1-388 dorotation
> trajout test.aligned.rst7
> run #### STEP1
> clear trajin
> reference test.aligned.rst7
> trajin md.trj 1 10
> rms reference mass :1-388
> trajout test_princi_rms.nc nc
> run ### STEP2
> clear trajin
> trajin test_princi_rms.nc
> rms reference mass :1-388 #### I have tried with and without this rms
> option; which is rather a repeat
> grid wat_grid.xplor 60 2 60 2 100 2 :WAT.O box ### Note different Z
> dimension
> run ### STEP3
>
> I am getting following problem:
>
> Using netcdf trajcteory I have checked that I get good Z-aligned structure
> (visually seen STEP2 traj file: test_princi_rms.nc) and I expect water to
> be aligned along Z axis too and make an outline shape corresponding to the
> length of polymer. Xplor file in VMD shows the water distribution gets the
> outline shape of polymer but not aligned along the Z axis and also I see
> clump of points at the corner of box (something observed when long molecule
> is not imaged properly and looks broken in parts).
>
> thanks a lot
> Jiom
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>



-- 
-------------------------
Daniel R. Roe, PhD
Department of Medicinal Chemistry
University of Utah
30 South 2000 East, Room 201
Salt Lake City, UT 84112-5820
http://home.chpc.utah.edu/~cheatham/
(801) 587-9652
(801) 585-6208 (Fax)
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Sat Mar 22 2014 - 15:30:03 PDT