Hi,
On Mon, Oct 28, 2013 at 7:58 AM, Subrata Paul <paul.subrata34.gmail.com> wrote:
> For atom: .R<Na+ 16>.A<Na+ 1> Could not find type: Na+
This issue has come up several times on the list (see e.g.
http://archive.ambermd.org/201204/0666.html etc). You need to load an
ion parameter set prior to adding ions. For example, to load the Joung
& Cheatham ion parameters for TIP3P:
loadamberparams frcmod.ionsjc_tip3p
See section 2.9 (Ions) of the AmberTools 13 manual for further details.
Hope this helps,
-Dan
--
-------------------------
Daniel R. Roe, PhD
Department of Medicinal Chemistry
University of Utah
30 South 2000 East, Room 201
Salt Lake City, UT 84112-5820
http://home.chpc.utah.edu/~cheatham/
(801) 587-9652
(801) 585-6208 (Fax)
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Mon Oct 28 2013 - 07:30:03 PDT