Re: [AMBER] Setting forcefield parameters

From: Jason Swails <jason.swails.gmail.com>
Date: Fri, 13 Sep 2013 10:03:21 -0400

On Fri, Sep 13, 2013 at 9:44 AM, Tanmoy Paul <tanmoy635.gmail.com> wrote:

> Hi,
> I am doing ONIOM calculations for RESP charge setup using gaussian
> 09. Now during optimization the VDW parameters for HW and HO are asked
> to be set as they are being set to zero in 'amber.prm' incorporated
> to gaussian 09.


That is because they _are_ set to 0 in most versions of the Amber force
field.

The idea is that the hydrogen is completely enclosed in the vdW radius of
the oxygen atom it is bonded to.

I have searched for the missing parameters in AMBER12
> parm . I have found two different VDW radius for HO ( one in
> 'parm99EP.dat' and another in 'parmpol12.dat') and no parameter
> corresponding to HW. I am confused regarding which one to pick for HO
> and where to find the parameters for HW.
>

Look in parm99.dat or parm10.dat or something like that. You are looking
at the polarizable force field parameter files (parmpol12.dat) and the
extra points (lone pairs)-based force field (parm99EP.dat). I believe that
ONIOM uses the standard, 'fixed-charge' force field.

HTH,
Jason

-- 
Jason M. Swails
BioMaPS,
Rutgers University
Postdoctoral Researcher
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber