Dear Amber supporters,
antechamber sometimes generates different(wrong) atom types and
force field parameters even if we use same molecule structures.
Results with AmberTools12 are as follows:
(molecule 1)
HETATM    1  C           0      -0.858   0.151   0.000
HETATM    2  C           0       0.521   0.151   0.000
HETATM    3  C           0       0.936   1.538   0.000
HETATM    4  C           0      -0.218   2.294  -0.000
HETATM    5  H           0      -1.632  -0.610  -0.000
HETATM    6  H           0       1.186  -0.708   0.000
HETATM    7  H           0       1.962   1.892  -0.000
HETATM    8  H           0      -0.448   3.355  -0.000
HETATM    9  C           0      -1.338   1.461  -0.000
HETATM   10  C           0      -2.636   1.849  -0.005
HETATM   11  H           0      -2.888   2.889  -0.008
HETATM   12  O           0      -3.674   0.865  -0.005
HETATM   13  H           0      -4.529   1.301  -0.007
=>
       cc
   cd             h4
           cc  c2
   cd             oh ho
       cc
(molecule 2, which is created by shuffling lines of molecule 1)
HETATM    3  C           0       0.936   1.538   0.000
HETATM    9  C           0      -1.338   1.461  -0.000
HETATM   12  O           0      -3.674   0.865  -0.005
HETATM   10  C           0      -2.636   1.849  -0.005
HETATM    8  H           0      -0.448   3.355  -0.000
HETATM    5  H           0      -1.632  -0.610  -0.000
HETATM    7  H           0       1.962   1.892  -0.000
HETATM    2  C           0       0.521   0.151   0.000
HETATM    1  C           0      -0.858   0.151   0.000
HETATM   13  H           0      -4.529   1.301  -0.007
HETATM    4  C           0      -0.218   2.294  -0.000
HETATM   11  H           0      -2.888   2.889  -0.008
HETATM    6  H           0       1.186  -0.708   0.000
=>
       cd
   cc             h4
           cd  c2
   cc             oh ho
       cd
Would you let me know why this happens?
What should I do for getting right result?
Best regards,
-- 
Hiromasa WATANABE
Manager, Ph.D.
HPC Dept., Technology Gr., HPC SYSTEMS Inc.
Head office: LOOP-X 8F, 3-9-15 Wangan, Minato-ku, Tokyo, Japan 108-0022.
Email: hi-watanabe.hpc.co.jp
www.hpc.co.jp
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Sun Aug 11 2013 - 20:00:03 PDT