Re: [AMBER] PME and vdW cutoffs

From: Andreas Goetz <agoetz.sdsc.edu>
Date: Tue, 7 May 2013 13:22:38 -0700

The cutoff applies to both electrostatics and vdW interactions. See also the discussion at
http://archive.ambermd.org/201006/0138.html

Under periodic boundary conditions, by default a continuum correction is used for the energy and pressure due to vdW interactions beyond the cutoff. See the keyword vdwmeth in the AMBER manual and page 65 in Allen/Tildesley "Computer Simulation of Liquids".

All the best,
Andy

On May 7, 2013, at 9:37 AM, George Tzotzos wrote:

> The Amber 11 manual, p. 36 reads " cut: This is used to specify the nonbonded cutoff, in Angstroms. For PME, the cutoff is used to limit direct space sum, and the default value of 8.0 is usually a good value".
>
> Does this apply to electrostatic interactions only or is it also applicable for van der Waals interactions too?
>
> Thanks in advance for any suggestions.
>
> Regards
>
> George
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber

--
Dr. Andreas W. Goetz
Assistant Project Scientist
San Diego Supercomputer Center
Tel  : +1-858-822-4771
Email: agoetz.sdsc.edu
Web  : www.awgoetz.de
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Tue May 07 2013 - 13:30:03 PDT