Re: [AMBER] leap - removing terminals problem

From: Jason Swails <jason.swails.gmail.com>
Date: Fri, 22 Mar 2013 13:05:09 -0400

My suggestion is to copy the leaprc file you are trying to use and remove
the residue mappings that cause chain-ending amino acids and nucleic acids
to be terminal residues.

That will prevent tleap from inserting the termini in the first place,
avoiding this whole issue.

HTH,
Jason

On Fri, Mar 22, 2013 at 11:59 AM, Ignacio J. General <ijgeneral.gmail.com>wrote:

> Dear Amber users,
>
> I am using tleap to generate the files I need for a thermodynamic
> integration of a protein+RNA+ions+water system. For the van der Waals step
> of TI, I need to build a system without the two terminals of RNA, but the
> rest should be exactly the same. So it is an unphysical system. The problem
> is that when I remove them in tleap, then it cannot generate the prmtop
> file; it segfaults.
>
> Here is what I am doing in tleap:
>
>
> -----------------------------------------------------------------------------
> source leaprc.ff10
> loadamberparams frcmod.ionsjc_tip3p
> loadamberparams magnesium.frcmod
> loadamberprep magnesium.prep
> C=loadpdb 1000_v0_l00.pdb
> A= copy C
> B= copy C
> remove B B.802
> remove B B.821
> set A box {101.7367567 101.7367567 101.7367567}
> set B box {101.7367567 101.7367567 101.7367567}
> saveamberparm A WT-ions-WAT8.prmtop 1000_v0_l00.rst
> saveamberparm B WT-ions-WAT8-no802.prmtop 1000_v1_l00.rst
> quit
>
> -----------------------------------------------------------------------------
>
> I tried many variations of the above script, different order of commands,
> removing the ions, etc., but nothing works. It always generates the files
> for system A, but not for B. They are empty. The error message for the last
> command is:
>
>
> -----------------------------------------------------------------------------
> > saveamberparm B WT-ions-WAT8-no802.prmtop
> 1000_v1_l00.rst
> Checking Unit.
> WARNING: There is a bond of 108.748183 angstroms between:
> ------- .R<G 820>.A<O3' 34> and �<`��
> 821>.s<367567 101.7367567
> 101.7367567} 62>
> WARNING: The unperturbed charge of the unit: 1.000000 is not zero.
>
> -- ignoring the warnings.
>
> Building topology.
> Building atom parameters.
> Building bond parameters.
> Could not find bond parameter for: OS - >
> Building angle parameters.
> Could not find angle parameter: CT - OS - >
> Could not find angle parameter: OS - > - O2
> /home/ijgeneral/Applications/amber12/bin/tleap: line 17: 1293 Segmentation
> fault $AMBERHOME/bin/teLeap -I$AMBERHOME/dat/leap/prep
> -I$AMBERHOME/dat/leap/lib -I$AMBERHOME/dat/leap/parm
> -I$AMBERHOME/dat/leap/cmd $*
>
> -----------------------------------------------------------------------------
>
> That warning with a bond of 108 A would certainly be a problem, but I have
> no idea why it appears there. I don't have such a thing in my system. And
> it doesn't exist when it generates the files for system A...
>
> Any ideas? This happens with AmberTools12 and 1.5.​​
>
> Thanks,
>
> Ignacio
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>



-- 
Jason M. Swails
Quantum Theory Project,
University of Florida
Ph.D. Candidate
352-392-4032
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Fri Mar 22 2013 - 10:30:03 PDT