Re: [AMBER] Question about AM1BCC

From: <steinbrt.rci.rutgers.edu>
Date: Thu, 14 Mar 2013 12:40:49 -0400 (EDT)

Hi

> Also, can anyone, give a more explicit wa to use Gaussian to calculate
> charges? Is there a special option that one needs to include in the
> gaussian calculation?

when you use antechamber to generate the gaussian input file, you will get
a job file that includes all necessary parameters for a subsequent RESP
calculation. check for the 'opt' keyword to see if gaussian is asked to do
an optimization first.

Likewise,for the AM1-BCC calculation, you can tell antechamber to keep
intermediate files, so you can check the sqm input for details of the
optimization procedure.

Thomas

Dr. Thomas Steinbrecher