Re: [AMBER] EGB discrepancy between sander and pmemd

From: Jason Swails <jason.swails.gmail.com>
Date: Tue, 4 Dec 2012 18:29:22 -0500

On Tue, Dec 4, 2012 at 6:02 PM, case <case.biomaps.rutgers.edu> wrote:

> On Tue, Dec 04, 2012, Eng H Yap wrote:
> >
> > I am still trying to set igb=0 as suggested by Dave, but it seems then
> > I'll need ntb=1, and I'll have to solvate the box in leap. Is that
> > right?
>
> Sorry: easier path is to set igb=6, which turns off GB, but doesn't require
> (or allow) ntb=1.
>

I'll see if your results are reproducible with my version...

pmemd actually prohibits all vacuum calculations -- there's a check against
igb==0 with ntb==0 and igb==6. igb==0 with ntb==0 and igb==6 are
sander-only options.

All the best,
Jason

-- 