Re: [AMBER] vlimit exceeded on step.. error

From: Jitesh Doshi <dosjitesh.gmail.com>
Date: Fri, 5 Oct 2012 17:41:37 +0530

yes.. i have run minimization in two steps.. restrained and then freeing
all the atoms. I am not sure as to how exactly I should start dissecting
the problem. Whatever i know about amber, things seems fine except I don't
know if something is wrong with the input file for the run which is:

Initial heating and equilabration
 &cntrl
  imin=0, irest=0, ntx=1,ig=-1,
  nstlim=100000, dt=0.001, ntc=1,
  ntpr=100, ntwx=10,
  ntr=1, restraint_wt=1, restraintmask=':1-356',
  cut=16, ntb=0, igb=0,
  ntt=3, gamma_ln=1.0,
  tempi=0.0, temp0=300.0,
 /

On Fri, Oct 5, 2012 at 5:28 PM, David A Case <case.biomaps.rutgers.edu>wrote:

> On Fri, Oct 05, 2012, Jitesh Doshi wrote:
>
> > first occurrence of vlimit exceeds appears at step 159, so it runs
> properly
> > till 158 steps.
>
> This ain't necessarily so. It may just mean the problems with the setup
> don't
> become severe enough until then to trigger the warning.
>
> > My temperature limits are 0 to 300. and i observe that in all those steps
> > where vlimit exceeds, temperature blows off beyond 300. Could this be the
> > reason for vlimit exceeding?
>
> It's the other way around: bad forces or collisions are leading to large
> local
> velocities. This is turn results in high temperatures. All these are just
> symptoms....you need to examine your simulation carefully to look for what
> might be causing the problem. Did you indeed run energy minimization
> first?
>
> ...dac
>
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>



-- 
Jitesh V. Doshi
Research Associate,
Bioinformatics Centre,
University of Pune.
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber