Hi,
I want to generate RESP charge of raloxifene. I have generated a GAMESS
input using the RED-tools for which i am getting a warning while running
gamess. my inputs are mentioned below. i think the coordinates of my
molecule are changed. Is that so? thanks in advance
 ECHO OF THE FIRST FEW INPUT CARDS -
 INPUT CARD> ! Keywords below are only useful for providing a starting
input...
 INPUT CARD> ! See the GAMESS-US
documentation...
 INPUT CARD> $CONTRL  ICHARG=0
MPLEVL=0
 INPUT CARD>          RUNTYP=OPTIMIZE SCFTYP=RHF
EXETYP=RUN
 INPUT CARD>          MULT=1 UNITS=ANGS
MAXIT=200
 INPUT CARD> !        INTTYP=HONDO QMTTOL=1.0E-08 ITOL=30
ICUT=20
 INPUT CARD>          COORD=CART
$END
 INPUT CARD> $SCF     DIRSCF=.T. CONV=1.0E-08
$END
 INPUT CARD> $SYSTEM  TIMLIM=50000 MWORDS=32 MEMDDI=0
$END
 INPUT CARD> $STATPT  NSTEP=200
OPTTOL=1.0E-06
 INPUT CARD>          HESS=CALC IHREP=10
$END
 INPUT CARD> $FORCE   METHOD=ANALYTIC VIBANL=.F.
$END
 INPUT CARD> $BASIS   GBASIS=N31 NGAUSS=6 NDFUNC=1
NPFUNC=0
 INPUT CARD>          DIFFSP=.F.
$END
 INPUT CARD> $GUESS   GUESS=HUCKEL
$END
 INPUT CARD>
$DATA
 INPUT CARD> GAMESS-US optimization output to be used by
R.E.D.
 INPUT CARD>
C1
 INPUT CARD> C     6.0     69.676  36.264
71.663
 INPUT CARD> H     1.0     70.368  35.905
72.329
 INPUT CARD> C     6.0     69.833  37.528
71.075
 INPUT CARD> H     1.0     70.648  38.097
71.320
 INPUT CARD> C     6.0     68.867  38.050
70.173
 INPUT CARD> O     8.0     68.904  39.304
69.677
 INPUT CARD> H     1.0     68.122  39.642
69.184
 INPUT CARD> C     6.0     67.761  37.239
69.837
 INPUT CARD> H     1.0     67.050  37.595
69.204
 INPUT CARD> C     6.0     67.621  35.977
70.405
 INPUT CARD> S    16.0     66.312  34.906
70.034
 INPUT CARD> C     6.0     67.053  33.711
71.057
 INPUT CARD> C     6.0     66.459  32.457
71.142
 INPUT CARD> C     6.0     66.211  31.711
69.955
 INPUT CARD> H     1.0     66.491  32.089
69.043
 INPUT CARD> C     6.0     65.589  30.460
70.008
 INPUT CARD> H     1.0     65.409  29.934
69.148
 INPUT CARD> C     6.0     65.182  29.929
71.247
 INPUT CARD> O     8.0     64.577  28.734
71.311
 INPUT CARD> H     1.0     64.127  28.476
72.139
 INPUT CARD> C     6.0     65.414  30.651
72.433
 INPUT CARD> H     1.0     65.126  30.247
73.329
 INPUT CARD> C     6.0     66.053  31.895
72.384
 INPUT CARD> H     1.0     66.218  32.406
73.256
 INPUT CARD> C     6.0     68.542  35.462
71.324
 INPUT CARD> C     6.0     68.199  34.192
71.735
 INPUT CARD> C     6.0     68.868  33.458
72.740
 INPUT CARD> O     8.0     69.395  32.392
72.429
 INPUT CARD> C     6.0     68.859  33.896
74.108
 INPUT CARD> C     6.0     69.769  33.338
75.036
 INPUT CARD> H     1.0     70.472  32.660
74.754
 INPUT CARD> C     6.0     69.722  33.708
76.403
   32000000 WORDS OF MEMORY AVAILABLE
                    * * * WARNING * * *
 OLD KEYWORD COORD=CART SELECTED, AUTOMATICALLY CHANGED TO COORD=PRINAXIS.
 YOUR MOLECULE'S COORDINATES WILL BE CHANGED TO PRINCIPAL AXES BY
   A) TRANSLATION TO THE CENTER OF MASS, THEN
   B) ROTATION TO HAVE A DIAGONAL MOMENT OF INERTIA TENSOR.
 HOWEVER, NOTHING ELSE IN YOUR INPUT WILL BE ROTATED IN THE SAME WAY,
 SO IF YOU HAVE A $VEC, $VIB, $GRAD, $HESS, EFP PARTICLE COORDINATES,
 OR ANYTHING ELSE THAT DEPENDS ON THE INITIAL ORIENTATION, THAT DATA
 WILL NOT BE USED CORRECTLY IN THIS RUN.
 THE PURPOSE OF COORD=PRINAXIS IS TO BE USED ONCE, ONLY AT THE VERY
 BEGINNING OF A SERIES OF COMPUTATIONS, PERHAPS TO FIND THE SYMMETRY
 UNIQUE ATOMS FROM AN ARBITRARY INITIAL ORIENTATION.
 AFTER THE FIRST RUN, YOU SHOULD USE ONLY COORD=UNIQUE, TO ENSURE THAT
 THE COORDINATES WHICH YOU READ IN ARE THE COORDINATES THAT ARE USED.
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Sat Sep 15 2012 - 05:30:04 PDT