[AMBER] GAMESS_RESP

From: Shomesankar Bhunia <rightclickatrighttime.gmail.com>
Date: Sat, 15 Sep 2012 08:15:25 -0400

Hi,
I want to generate RESP charge of raloxifene. I have generated a GAMESS
input using the RED-tools for which i am getting a warning while running
gamess. my inputs are mentioned below. i think the coordinates of my
molecule are changed. Is that so? thanks in advance



 ECHO OF THE FIRST FEW INPUT CARDS -
 INPUT CARD> ! Keywords below are only useful for providing a starting
input...
 INPUT CARD> ! See the GAMESS-US
documentation...
 INPUT CARD> $CONTRL ICHARG=0
MPLEVL=0
 INPUT CARD> RUNTYP=OPTIMIZE SCFTYP=RHF
EXETYP=RUN
 INPUT CARD> MULT=1 UNITS=ANGS
MAXIT=200
 INPUT CARD> ! INTTYP=HONDO QMTTOL=1.0E-08 ITOL=30
ICUT=20
 INPUT CARD> COORD=CART
$END
 INPUT CARD> $SCF DIRSCF=.T. CONV=1.0E-08
$END
 INPUT CARD> $SYSTEM TIMLIM=50000 MWORDS=32 MEMDDI=0
$END
 INPUT CARD> $STATPT NSTEP=200
OPTTOL=1.0E-06
 INPUT CARD> HESS=CALC IHREP=10
$END
 INPUT CARD> $FORCE METHOD=ANALYTIC VIBANL=.F.
$END
 INPUT CARD> $BASIS GBASIS=N31 NGAUSS=6 NDFUNC=1
NPFUNC=0
 INPUT CARD> DIFFSP=.F.
$END
 INPUT CARD> $GUESS GUESS=HUCKEL
$END
 INPUT CARD>
$DATA

 INPUT CARD> GAMESS-US optimization output to be used by
R.E.D.
 INPUT CARD>
C1

 INPUT CARD> C 6.0 69.676 36.264
71.663
 INPUT CARD> H 1.0 70.368 35.905
72.329
 INPUT CARD> C 6.0 69.833 37.528
71.075
 INPUT CARD> H 1.0 70.648 38.097
71.320
 INPUT CARD> C 6.0 68.867 38.050
70.173
 INPUT CARD> O 8.0 68.904 39.304
69.677
 INPUT CARD> H 1.0 68.122 39.642
69.184
 INPUT CARD> C 6.0 67.761 37.239
69.837
 INPUT CARD> H 1.0 67.050 37.595
69.204
 INPUT CARD> C 6.0 67.621 35.977
70.405
 INPUT CARD> S 16.0 66.312 34.906
70.034
 INPUT CARD> C 6.0 67.053 33.711
71.057
 INPUT CARD> C 6.0 66.459 32.457
71.142
 INPUT CARD> C 6.0 66.211 31.711
69.955
 INPUT CARD> H 1.0 66.491 32.089
69.043
 INPUT CARD> C 6.0 65.589 30.460
70.008
 INPUT CARD> H 1.0 65.409 29.934
69.148
 INPUT CARD> C 6.0 65.182 29.929
71.247
 INPUT CARD> O 8.0 64.577 28.734
71.311
 INPUT CARD> H 1.0 64.127 28.476
72.139
 INPUT CARD> C 6.0 65.414 30.651
72.433
 INPUT CARD> H 1.0 65.126 30.247
73.329
 INPUT CARD> C 6.0 66.053 31.895
72.384
 INPUT CARD> H 1.0 66.218 32.406
73.256
 INPUT CARD> C 6.0 68.542 35.462
71.324
 INPUT CARD> C 6.0 68.199 34.192
71.735
 INPUT CARD> C 6.0 68.868 33.458
72.740
 INPUT CARD> O 8.0 69.395 32.392
72.429
 INPUT CARD> C 6.0 68.859 33.896
74.108
 INPUT CARD> C 6.0 69.769 33.338
75.036
 INPUT CARD> H 1.0 70.472 32.660
74.754
 INPUT CARD> C 6.0 69.722 33.708
76.403
   32000000 WORDS OF MEMORY AVAILABLE


                    * * * WARNING * * *
 OLD KEYWORD COORD=CART SELECTED, AUTOMATICALLY CHANGED TO COORD=PRINAXIS.
 YOUR MOLECULE'S COORDINATES WILL BE CHANGED TO PRINCIPAL AXES BY
   A) TRANSLATION TO THE CENTER OF MASS, THEN
   B) ROTATION TO HAVE A DIAGONAL MOMENT OF INERTIA TENSOR.

 HOWEVER, NOTHING ELSE IN YOUR INPUT WILL BE ROTATED IN THE SAME WAY,
 SO IF YOU HAVE A $VEC, $VIB, $GRAD, $HESS, EFP PARTICLE COORDINATES,
 OR ANYTHING ELSE THAT DEPENDS ON THE INITIAL ORIENTATION, THAT DATA
 WILL NOT BE USED CORRECTLY IN THIS RUN.

 THE PURPOSE OF COORD=PRINAXIS IS TO BE USED ONCE, ONLY AT THE VERY
 BEGINNING OF A SERIES OF COMPUTATIONS, PERHAPS TO FIND THE SYMMETRY
 UNIQUE ATOMS FROM AN ARBITRARY INITIAL ORIENTATION.

 AFTER THE FIRST RUN, YOU SHOULD USE ONLY COORD=UNIQUE, TO ENSURE THAT
 THE COORDINATES WHICH YOU READ IN ARE THE COORDINATES THAT ARE USED.
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Sat Sep 15 2012 - 05:30:04 PDT