[AMBER] problem during heating up the system

From: Sanjib Paul <sanjib88paul.gmail.com>
Date: Wed, 20 Jun 2012 15:43:42 +0530

Dear Amber User,
                   I am simulating HCAII using 2CBA.pdb. I am using
CaDA approach. I have changed residue name as given in the paper
"Novel Zinc Protein Molecular Dynamics Simulation: Steps Toward
Antiangiogenesis for Cancer Treatment, Yuan-Ping Pang, J. Mol. Model.
1999,5,196-202," After minimisation I have heated up the system using
following input file,
 heating of whole system
 &cntrl
  imin = 0,
  irest = 0,
  iwrap = 1,
  ntx = 1,
  ntb = 1,
  ntc = 2,
  ntf = 2,
  ntt = 3,
  ntr = 1,
  cut = 20.0,
  tempi = 0.0,
  temp0 = 300.0,
  gamma_ln = 1.0,
  nstlim = 25000,
  dt = 0.002,
  ntpr = 100,
  ntwx = 100,
  ntwr = 1000
 /
Keep protein fixed with weak restraint
3.0
RES 1 265
END
END

But, I am getting a follwing error, and run stopped after a time.

vlimit exceeded for step 3680; vmax = 290.4790
vlimit exceeded for step 3681; vmax = 5167.6693

     Coordinate resetting (SHAKE) cannot be accomplished,
     deviation is too large
     NITER, NIT, LL, I and J are : 0 0 2017 4081 4082

     Note: This is usually a symptom of some deeper
     problem with the energetics of the system.

So, please give some tips so as I can complete it.

Thanking you
Sanjib

_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Jun 20 2012 - 03:30:02 PDT
Custom Search