Re: [AMBER] Comaring energy values after restart

From: case <case.biomaps.rutgers.edu>
Date: Sat, 25 Feb 2012 09:26:11 -0500

On Sat, Feb 25, 2012, Dilraj LAMA wrote:

> I was running a simulation which got stalled after a
> period due to some reason. I was saving the restart file (.rst) every
> one nanosecond. Hence I restarted the job with the latest restart file
> as input. Then I compared the energy values in the beginning of the
> new run and the value at the same time step in the old simulation.
>
> I was expecting the energy values to be identical. However they are
> not. Below are the values from the two simulation run.
>
> NEW SIMULATION:
>
> NSTEP = 500 TIME(PS) = 32531.000 TEMP(K) = 301.10 PRESS = 39.9
> Etot = -94460.3737 EKtot = 23209.8266 EPtot = -117670.2004
>
> OLD SIMULATION:
>
> NSTEP = 16000500 TIME(PS) = 32531.000 TEMP(K) = 302.19 PRESS = -128.7
> Etot = -94254.9707 EKtot = 23294.4062 EPtot = -117549.3769
>
> I would expect the values to be identical in both cases since I am
> restarting my simulation with the same coordinate and velocity values
> at this particular time step supplied through restart file.
>

I think Dan's reply is wrong in this case. The more likely culprit is that
saving to a restart file, then restarting loses some precision. When running
MD, small differences in starting coordinates (or velocities) quickly produces
divergent trajectories. This is discussed in the "testing" section of the
Users' Manual.

To see what happens with a restart, run a short simulation (say 500 steps)
with ntpr=1, then break it into two parts, again with ntpr=1. You should
see initial agreement, but by 500 steps, things generally will have
diverged.

....hope this helps....dac


_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Sat Feb 25 2012 - 06:30:02 PST