Re: [AMBER] TI_All non-softcore atoms must be identical in both systems

From: leila karami <karami.leila1.gmail.com>
Date: Sun, 19 Feb 2012 17:50:34 +0330

Dear Dr. Thomas Steinbrecher

Thanks for your reply.

As you said, if I build a single pdb-file of my system with water and ions,

how to change GC base pair to AT?


Thanks in advance.



On Sun, Feb 19, 2012 at 4:35 PM, <steinbrt.rci.rutgers.edu> wrote:

> Hi,
>
> > this process: 21890 atoms, partner process: 23383 atoms
> > SANDER BOMB in subroutine setup_sc
> > All non-softcore atoms must be identical in both systems
> [...]
> > Since number of Na ions for neutrality of the both systems is the same,
> > this difference in number of atoms corresponds to water molecules.
>
> You cannot build the two end states independently. All atoms, except the
> ones in your scmasks must be identical in their starting positions and
> order in the prmtop. It may be easiest to built a single pdb-file of your
> system with water and ions and read it into leap twice, just changing the
> residue name or something similar to build V0 and V1.
>
> Thomas
>
> Dr. Thomas Steinbrecher
> formerly at the
> BioMaps Institute
> Rutgers University
> 610 Taylor Rd.
> Piscataway, NJ 08854
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Sun Feb 19 2012 - 06:30:02 PST