Dear all,

When I used antechamber with mopac to do ligand charge calculation, the
charge calculation failed because antechamber or mopac generated a keyword
in the mopac.in, ANALYT, which stopped ligand charege calculation. I am
wondering if someone knows how to let antechamber or mopac not to generate
the keyword ANALYT so the whole charge calculation can continue. Or, how
can I start charge calculation with the file mopac.in after I remove the
keyword inside? I use Amber 11 and MOPAC 2009, and I attach the error
message as your reference. Any suggestion is highly appreciated!

Sincerely,

Crystal

=============error message================
[CrystalKu.oolite mopac]$ $AMBERHOME/exe/antechamber -fi pdb -fo mol2 -i
TPP.pdb -o TPP_am1bcc.mol2 -nc -1 -c bcc -df 0 -s 2

Running: /opt/amber/bin/bondtype -j full -i ANTECHAMBER_BOND_TYPE.AC0 -o
ANTECHAMBER_BOND_TYPE.AC <http://antechamber_bond_type.ac/> -f ac

Info: Bond types are assigned for valence state 2 with penalty of 1

Running: /opt/amber/bin/atomtype -i ANTECHAMBER_AC.AC0 -o
ANTECHAMBER_AC.AC<http://antechamber_ac.ac/> -p
gaff

Total number of electrons: 222; net charge: -1

Running: /opt/amber/bin/mopac.sh
Error: unable to find mopac charges in mopac.out
       Examine that file for evidence of errors
[CrystalKu.oolite mopac]$ more mopac.out
 *******************************************************************************
 ** Site#: 13093 For non-commercial use only Version
11.038L **
 *******************************************************************************
 ** Cite this work as: MOPAC2009, James J. P. Stewart, Stewart
Computational **
 ** Chemistry, Version 11.038L web:
HTTP://OpenMOPAC.net<http://openmopac.net/> Days
remaining: 54 **
 *******************************************************************************
 **
  **
 ** MOPAC2009
   **
 **
  **
 *******************************************************************************

                            AM1 CALCULATION RESULTS


 *******************************************************************************
 * CALCULATION DONE: Thu Dec 15 15:18:44
2011 *
 * AM1 - The AM1 Hamiltonian to be used
 * GEO-OK - OVERRIDE INTERATOMIC DISTANCE CHECK
 * MMOK - APPLY MM CORRECTION TO CONH BARRIER
 *
 *
 *
 * CHARGE ON SYSTEM = -1
 *
 *
 *
 * PRECISE - CRITERIA TO BE INCREASED BY 100 TIMES
 * T= - A TIME OF 172800.0 SECONDS REQUESTED
 * DUMP=N - RESTART FILE WRITTEN EVERY 7200.000 SECONDS



          UNRECOGNIZED KEY-WORDS: ( ANALYT)



          IF THESE ARE DEBUG KEYWORDS, ADD THE KEYWORD "DEBUG"
 *
 * Errors detected in keywords. Job stopped here to avoid wasting time.
 *
 *******************************************************************************
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Fri Dec 16 2011 - 17:00:02 PST