Re: [AMBER] Adaptively Biased Molecular Dynamics

From: Aron Broom <broomsday.gmail.com>
Date: Tue, 6 Dec 2011 20:58:59 -0500

Yes, I was actually just looking at that part of the user guide, seems like
it is indeed the solution to the boundary problem. Thanks :)

I noticed also from this section the com(i1, i2, i3) style of syntax which
specifies a center of mass. I tried to use that in my mdin file, changing:

 variable
  type = DISTANCE
  i = (1, 5)
  min = 0.0
  max = 10.0
  resolution = 0.05
 end variable
end ncsu_abmd

to

 variable
  type = DISTANCE
  i = (com(1,2,3,4), com(5,6,7,8))
  min = 0.0
  max = 10.0
  resolution = 0.05
 end variable
end ncsu_abmd

but this throws an error claiming that it isn't happy about seeing a second
open-bracket in there. I tired square and curly brackets also, but to no
avail. Has anyone used center of masses with collective variables in
AMBER? I imagine it must be quite common?



On Tue, Dec 6, 2011 at 8:51 PM, case <case.biomaps.rutgers.edu> wrote:

> On Tue, Dec 06, 2011, Aron Broom wrote:
> >
> > 2) I ran the water dimer test just using the oxygens for each water and
> the
> > PMF is semi-reasonable, but the entire simulation suffers from the fact
> > that the distance can become larger than the range I'm interested in.
>
> You could use a "flat bottom" NMR-type constraint to keep the O=O distance
> from getting too big, e.g.
>
> &rst iat = 3,6, r1=0.1, r2=2.0, r3=12.0, r4=99.0, rk2 = 0.0, rk3=10.0, /
>
> This (untested!) restraint will have no effect until the distance between
> atoms 3 and 6 gets to 12 Ang, and then the energy will rise quickly,
> pushing
> the two molecules back together.
>
> ....dac
>
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>