Re: [AMBER] REMD umbrella sampling

From: Daniel Sindhikara <sindhikara.gmail.com>
Date: Tue, 29 Nov 2011 18:48:23 +0900

If you mean doing replica exchanges between umbrellas, then yes, I have
demonstrated that in the reweighting program manuscript I referenced
earlier: http://www.sciencedirect.com/science/article/pii/S0010465511001640

It can be done using the NCSU package. You should check the NCSU/ABMD
section of the AMBER manual for details. Unfortunately, as of AMBER11 I
believe there is a restriction that all replica modes should
be a different temperature. I got around this by incrementing the modes by
0.1K. This is essentially tricking AMBER into doing REUS "Replica exchange
umbrella sampling". Perhaps in a future release there will
be a more straightforward way to do it.

-Dan

On Tue, Nov 29, 2011 at 1:13 PM, caobb0214 <caobb0214.163.com> wrote:

> dear all,
>
> I am wondering if it is possible to carry out REMD umbrella sampling with
> Amber to calculate free energy barrier.
> Any suggestion in this regard is welcome.
>
>
>
>