Re: [AMBER] problem with gas-phase MD simulation in Amber8.

From: Ross Walker <ross.rosswalker.co.uk>
Date: Fri, 18 Mar 2011 10:54:00 -0700

Set ntb=0. I also suggest setting cut=999.0 for a gas phase simulation.

> -----Original Message-----
> From: marta wi¶niewska. [mailto:m.wisniewska.aol.pl]
> Sent: Friday, March 18, 2011 10:13 AM
> To: amber.ambermd.org
> Subject: Re: [AMBER] problem with gas-phase MD simulation in Amber8.
>
> hi,
>
>
> well, for what exactly I must change ntb? because I don't have any idea.
>
>
> best regards,
> martha.
>
>
>
>
>
>
> -----Original Message-----
> From: steinbrt <steinbrt.rci.rutgers.edu>
> To: AMBER Mailing List <amber.ambermd.org>
> Sent: Fri, 18 Mar 2011 9:23
> Subject: Re: [AMBER] problem with gas-phase MD simulation in Amber8.
>
>
> Hi,
>
> also, your input file had ntb=1, that is not a gas-phase simulation but a
> periodic box one. If you run that input file with a vacuum prmtop, your
> simulation will stop with an error.
>
> Kind Regards,
>
> Thomas
>
> Dr. Thomas Steinbrecher
> formerly at the
> BioMaps Institute
> Rutgers University
> 610 Taylor Rd.
> Piscataway, NJ 08854
>
> _______________________________________________
> AMBER mailing list
> AMBER.ambermd.org
> http://lists.ambermd.org/mailman/listinfo/amber
>
>
>
> _______________________________________________
> AMBER mailing list