> a minute). Then it stabilizes itself at this temperature. The actual
> simulation consists of many 500 pico second runs. I decided to use
> this time scale right after i had this NaN errors in the first time.
> My reasoning based on the observation of first set of NaN s in a
> longer run. Back in that time fine part of the .rst file was close to
> 800 pico seconds. Then this leads me to divide it into 500 pico second
> steps. Again for those runs, i am using a cutoff distance 10 A.
> iwrap=1 flag/options is included. But, I am not utilizing ig=-1
> flag/option. Basically my input file is exactly same with the input
> file
> in advanced web tutorial for explicit solvent case except this iwrap
option.
"but I am not utilizing ig=-1"
Don't do this..., unless you are setting the ig value manually to a
different value for each restart. If you are using ntt=3 this can be
disastrous.
See: http://pubs.acs.org/doi/abs/10.1021/ct8002173
All the best
Ross
/\
\/