Dear Amber users,
I am trying to create a rectangular cuboid system and end up having 
vacuum bubbles while heating the system up to 300 K. I am thinking that 
the problem is with the box info I manually enter to the inpcrd file. 
Therefore, I want to understand how sander/pmemd does reading of box 
information while doing the calculations. I have a couple of questions and 
will appreciate any response. Thanks in advance.
1. After creating the inpcrd file using 'setbox mol centers', the last 
line in inpcrd file is
   61.3200000  59.8490000  68.9990000  90.0000000  90.0000000  90.0000000
When I check out the .pdb file that was used to create the inpcrd/prmtop 
files, the minimum and maximum x,y,z coordinates/points are (0.137,61.457) 
for x, (-0.099,59.750) for y, and (0.016,69.015) for z. How does the 
program understand how to put the cells next to each other? Also, when the 
simulation is run, the water molecules fly to the neighbouring cells, and 
let's say I have that .rst file at hand. When I try to put the atoms in 
this .rst file into the primary cell/box, how does the program do the 
calculation? Is there a reference point the program calculates before 
putting the atoms into the primary cell?
2.In the above inpcrd file, delta(x) is 61.457-0.137=61.320 (max_x - 
min_x), which is the length of the x-axis in the rectangular cuboid. The 
same is true for y and z; delta(y) and delta(z) are exactly equal to 
59.849 and 68.999.
If the first atom in the .pdb file has the (x,y,z) coordinates of (0.137, 
-0.099,64.247), is one of the images in the neighboring cell will have a 
coordinate of (0.137+61.3200000, -0.099,64.247)? If yes, will the 
images of the rest of the atoms be created the same way?
3. The system that I prepared has 2 surfaces/planes (top, bottom) that are 
filled with water+ions in between and the whole system looks like 
rectangular cuboid. The surfaces/planes are not PURE rectangular cuboids, 
however. Yet they can repeat on x,y,z axis when the right delta(x), 
delta(y) and delta(z) is used. For instance, in VMD, when I set the box 
information as a=61.32, b=60.69106, c=71.38317, and alpha=beta=gamma=90, 
and look at the periodic cells, I see the right repetition of the 
surfaces/planes on x,y,z axis. Can I use these a,b,c values and replace 
the last line of inpcrd with these ones?
Thanks in advance for your responses. Best regards,
   Ilyas Yildirim, Ph.D.
   -----------------------------------------------------------
   = Department of Chemistry         -    2145 Sheridan Road =
   = Northwestern University         -    Evanston, IL 60208 =
   = Ryan Hall #4035 (Nano Building) -    Ph.: (847)467-4986 =
   = 
http://www.pas.rochester.edu/~yildirim/                 =
   -----------------------------------------------------------
_______________________________________________
AMBER mailing list
AMBER.ambermd.org
http://lists.ambermd.org/mailman/listinfo/amber
Received on Wed Nov 03 2010 - 15:00:03 PDT