[AMBER] inconsistency between steered Md and GBSA

From: MEHMET ALI OZTURK <mehozturk.ku.edu.tr>
Date: Sat, 18 Sep 2010 22:57:37 +0300

Hi,

I am investigating the binding free energy of a pentapeptide to a receptor
with Steered MD and GBSA . For SMD I have used,

"Constant velocity SMD simulation with force constant k=7 and velocity
0.00001 Å/ps until work graphics are converged. "

For GBSA the following is done,

Internal dielectric constant is taken 2 and external dielectric constant is
80. Bondi radii is used as 2 Ǻ for GB analysis. LCPO method is used with γ
value taken as 0.005 and β value taken as 0 for nonpolar
contributions.Entropy terms are calculated by NMODE module with ε = 4Ri.



For SMD binding free energy is found to be -3,5 kcal/mole ; but from GBSA it
is found -7,33 kcal/mol.


Can anybody help for the reason of this difference?


Thanks in advance,

Mehmet Ali Öztürk