Re: AMBER: PB Radii

From: Swarup Gupta <swarupgupta.yahoo.com>
Date: Sat, 15 Nov 2008 19:44:25 -0800 (PST)

Thank a lot for your response.
 
Now I wish to know if I use igb=2 or igb=5 keeping the default dielectric radii set then the result would be worng or not reliable at all? I am trying to calculate binding free energy from MMGBSA calculation by postprocessing a trajectory which was originally run with explicit water.
 
regards,
S Gupta 
 


--- On Thu, 11/13/08, David A. Case <case.biomaps.rutgers.edu> wrote:

From: David A. Case <case.biomaps.rutgers.edu>
Subject: Re: AMBER: PB Radii
To: amber.scripps.edu
Date: Thursday, November 13, 2008, 6:01 AM

On Wed, Nov 12, 2008, Swarup Gupta wrote:

> I want to know if I use IGB=2 while keeping the default radii set then
> whether the results would be wrong!! The manual says that "With this
option,
> you should use the LEaP command "set default PBradii
mbondi2"......but my
> confusion is that I am not working with PB; then what is the use of
setting
> a PBradii here while running GB?

The term "PBradii" might better be named
"continuum_electrostatics_radii" or
"dielectric radii". They are used for both GB and PB calculations.

...dac

-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" (in the *body* of the email)
      to majordomo.scripps.edu

-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" (in the *body* of the email)
      to majordomo.scripps.edu
Received on Fri Dec 05 2008 - 14:54:14 PST
Custom Search