On Fri, Nov 16, 2007, Yamada, Takahiro wrote:
> 
> I have a special system which is butadiene-acrylonitrile-butadiene
> monomer solvated with TIP3PBOX.  I exactly followed Tutorial B4 (sustiva
> solvated with TIP3PBOX) to make prmtop and inpcrd.  Then I tried to run
> sander, but I failed to run.  The end on output file said "Error:
> ifbox=2 in prmtop but angles are not correct."  Attached are prmtop,
> inpcrd, out, and 2 pdb files (one for original
> butadiene-acrylonitrile-butadiene monomer, and one for monomer solvated
> with water which I recreated using ambpdb command).  I appreciate if
> anyone could tell me what is wrong.  I am new AMBER user and trying to
> apply AMBER code to model polymer - organic solvent interaction.  I
> created this system as a 1st step to examine if AMBER can be used for my
> research.
In your input file, you set ntb=0, but this would not be correct for a
solvated system, which is always periodic.
Sander gets confused at this point.  It should give a better error message
(e.g. check first that ntb=0 but a nonzero ifbox).  Still, the fix should be
easy: don't set ntb=0 for periodic simulations.
...good luck...dac
-----------------------------------------------------------------------