AMBER: error while Running TMD

From: gurpreet singh <gps.iitm.gmail.com>
Date: Wed, 17 Oct 2007 23:51:18 +0530

Hello Amber users

I am using Amber 9 , I want to apply TMD on a inhibitor docked to my
protein. While running the TMD I am getting the following error"

Coordinate resetting (SHAKE) cannot be accomplished,
     deviation is too large
     NITER, NIT, LL, I and J are : 0 0 1620 3196 3197

     Note: This is usually a symptom of some deeper
     problem with the energetics of the system.

Generally to recver from this problem reduction in the force constant ot
time step is the good idea
but here IN TMD I am not all using any restraints so what else is the reason
for this.

My input file :

&cntrl
  imin = 0, ntx = 7, irest = 1,
  ntpr = 100, ntwx = 500, ntwe = 0,
  ntc = 2, ntf = 2,
  nstlim = 250000, dt = 0.002,
  tempi=300.0, temp0 = 300.0, ntt =1, tautp =2.0,
  ntb = 1, ntp = 0,cut=10.0,iwrap=1,ntr=0,
  itgtmd=1,tgtrmsd=11.11, tgtmdfrc=5.0, tgtrmsmask=":321",tgtfitmask=":
1-320.CA,C,N"
 &end

  &wt type='TGTRMSD', istep1 =0,istep2 = 50000,value1 = 11.11,
            value2 = 5.55, &end
  &wt type='TGTRMSD', istep1 =50001, istep2 = 250000,value1 = 5.55,
            value2 = 0.0, &end
  &wt type="END" &end


 here I am using such a high value of RMSD I dont know whether it is
fissible or not. Suggest something.


Thanks & Regards

Gurpreet

-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Sun Oct 21 2007 - 06:07:12 PDT
Custom Search