> > how to solvate this system, but I think the best strategy would be to hold
> > the protein with tight restraints for successive additions of water
> > molecules and simulation in the NVT ensemble, then simulation in the NPT
> > ensemble while maintaining the protein atom restraints as small numbers of
> > water molecules are added or taken away until the pressure stabilizes at
> > 1atm with the right unit cell volume.
>
> You are right that figuring out how many waters to add, and where they should
> go, is a challenging task. You need to try to get the starting configuration
> as good as possible, since the time required to relax waters from "bad"
> positions to good ones might be prohibitively long. You might look at packmol
A couple of papers by Darden and co-workers (one is Bevan et al in BJ in
~2000) used constant pressure equilibration of the full crystal to find
the correct number of waters. Also, beyond packmol, you could try Mezei's
software simulaid (
http://fulcrum.physbio.mssm.edu/~mezei/simulaid/).
-- tom
p.s. I do not think CHARMM has any special way of doing this, re:
equilibration of solvent/ions in a crystal lattice.
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Wed Aug 15 2007 - 06:07:37 PDT