AMBER: Cutoff list exceeds largest sphere in unit cell

From: Andrew Borgert <borg0109.umn.edu>
Date: Fri, 13 Jul 2007 11:18:05 -0500

Using AMBER9 on an intel linux workstation, I am running MD on a very small
glycopeptide with explicit solvent, and I got the following error part way
through the run:



Cutoff list exceeds largest sphere in unit cell!!
 Big problems with imaging!!
 a,b,c = 29.3936780883931 29.3936780883931
   29.3936780883931
 alpha,beta,gamma = 109.471219000000 109.471219000000
   109.471219000000
 cutlist,sphere = 12.0000000000000 11.9999194351816


The MD run has the following parameters which I have used before without
problem:
 &cntrl
  imin=0,
  irest = 1,
  ntx = 7,
  ntb = 2, pres0 = 1.0, ntp = 1, taup = 2.0,
  cut = 10,
  ntr = 0,
  ntc = 2,
  ntf = 2,
  tempi = 300.0,
  temp0 = 300.0,
  ntt = 3,
  gamma_ln = 1.0,
  nstlim = 100000, dt = 0.001,
  ntpr = 200, ntwx = 200, ntwr = 200
 /

The system was setup in xLeap, and water added using the following command:

solvateoct m TIP3PBOX 9.0

Any suggestions?


-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Sun Jul 15 2007 - 06:07:41 PDT