AMBER: ntt=1 or ntt= 3?

From: Therese Malliavin <terez.pasteur.fr>
Date: Wed, 21 Mar 2007 18:32:07 +0100

Dear AMBER users,

I have a couple of questions about the parameters ntt. I have seen that
several questions have been asked in the past, for versions 7 and 8 of
AMBER, but there are some changes in the documentation of AMBER9, and I
have some trouble with them. So I apologize if the question was already
asked for AMBER 9 (I checked on the archive of the mailing list and did
not find anything).

In documentation of AMBER 8, one finds that ntt=1 and tautp=0.2 are
proposed for the example (p. 103) of usual MD in the NTP ensemble.

In documentation of AMBE 9, the user is told not to use ntt=1: "Unless
you are sure you know what you are doing, please don't use ntt=1!" (p.
103) , and ntt=3 and gamma_ln=1.0 are proposed in the example (p. 96)
for usual MD in the NTP ensemble.

So, I decided to switch from ntt=1 to ntt=3 for running an usual MD
simulation in the NTP ensemble (without QMMM). Before that, I was
heating the system using ntt=1 and a constant volume ensemble.

But, the equilibration simulation has a problem with the water density
which is about 0.84 in place of slightly larger than 1. Also, the
pressure is switched to negative values (mean pressure calculated over
20 ps is about -100 atm, whereas I always found it around 0 in the past
when I was using ntt=1).

So, I would greatly appreciate to have some explanation about the setup
of thermostats in AMBER 9, and about the input values recommended for
the different uses of sander.

Best regards,

Thérèse Malliavin
CNRS research fellow
Unité de Bioinformatique Structurale
Institut Pasteur de Paris

-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Sun Mar 25 2007 - 06:07:14 PDT