AMBER: antechamber error

From: Ilyas Yildirim <yildirim.pas.rochester.edu>
Date: Sat, 17 Mar 2007 02:44:57 -0400 (EDT)

Dear All,

I have a structure, which has 54-55 atoms in it. I am trying to use
antechamber to assign the bond type/atom type info, but I am getting the
following error message (which I am not sure what it means):

antechamber -i part1_CH3_connect.pdb -fi pdb -o part1_CH3_connect.prepi
-fo prepi -c bcc -at gaff -nc 0 &
[1] 25421

Warning: the assigned bond types may be wrong, please :
(1) double check the structure (the connectivity) and/or
(2) adjust atom valence penalty parameters in APS.DAT, and/or
(3) increase MAXVASTATE in define.h and recompile bondtype.C
(4) increase PSCUTOFF in define.h and recompile bondtype.C
    Be cautious, use a large value of PSCUTOFF (>10) will significantly
increase the computer time
Error: cannot run "/programs/amber9/exe/bondtype -i
ANTECHAMBER_BOND_TYPE.AC0 -o ANTECHAMBER_BOND_TYPE.AC -f ac -j full" in
judgebondtype() of antechamber.c properly, exit

[1] Done antechamber -i part1_CH3_connect.pdb
-fi pdb -o part1_CH3_connect.prepi -fo ...

The structure is neutral. I tried to google but could not find any useful
info on this error message. Any help is greatly appreciated. Thanks.

Best,

-- 
  Ilyas Yildirim
  ---------------------------------------------------------------
  - Department of Chemisty       -				-
  - University of Rochester      -				-
  - Hutchison Hall, # B10        -				-
  - Rochester, NY 14627-0216     - Ph.:(585) 275 67 66 (Office)	-
  - http://www.pas.rochester.edu/~yildirim/			-
  ---------------------------------------------------------------
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu