Dear Ross
Thanks for your previous help.
>> I built the system from a few TIP3PBOXs, manually adjusted the box
>> dimensions to give the correct density at 300K, performed a
>> few thousand
>> minimisation steps (about half steepest descent), then
>> performed MD from
>> 0K -> 300K over 100ps, followed by another 100ps at 300K, both NVT.
>
> Was this with QM/MM MD? If so then is definately a problem with
> incompatibility ofr dumpfrc and QMMM.
No, this was done classically. I've bitten the bullet and am now
equilibrating a larger (45A cube) box of water, again classically:
10000 steps minimisation (2000 steepest descent)
200ps NVT 0K -> 300K
1ns NPT 300K
Should I do some minimisation after this with QM/MM turned on before I
do QM/MM MD?
> The safer way would just be to put a write(20,*) f(1:3*natom) at the end of
> the force routine followed by a call to mexit but this obviously involved
> adding a couple of lines to force.f. I don't know if you would be okay to do
> this or not.
Thanks for the suggestion.
Regards,
Steve.
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Sun Mar 04 2007 - 06:07:53 PST