Hi Rima,
Lines like "ESP Fit Center **** is at  -5.881150  1.189846 -4.380049" in
gout should not produce an error. I would like to figure out what
happened if you send me your gout file.
 
Best
 
Junmei
 
        Subject: AMBER: gaussian output to prepin problem
        
        
        Hello! 
         
        I am trying to generate topology files for a ligand. I ran
gaussian and tried to generate the prepin file from the .gout (gaussian
output), on checking the output i.e. the .prepin file, it seems that the
charges are not being read and the last column remains to be 0.000.
         
        Hence, I tried to use the following command (step by step
approach) 
         
        antechamber -fi gout -fo ac -i resp631_GSJ.out -o
respgen_GSJ_input.ac -c resp
           
         Amber8 Module: resp 
          
        forrtl: severe (24): end-of-file during read, unit 5, file
/home/rchaud/gaussian/ANTECHAMBER_RESP1.IN
        Image              PC        Routine
Line        Source             
        resp               080A90B4  Unknown               Unknown
Unknown
        resp               080A7C8C  Unknown               Unknown
Unknown
        resp               0808705D  Unknown               Unknown
Unknown
        resp               0805CB50  Unknown               Unknown
Unknown 
        resp               0805D027  Unknown               Unknown
Unknown
        resp               0806B0BA  Unknown               Unknown
Unknown
        resp               0804A69B  Unknown               Unknown
Unknown
        resp               0804A4BA  Unknown               Unknown
Unknown 
        resp               0804A341  Unknown               Unknown
Unknown
        Unknown            00134E33  Unknown               Unknown
Unknown
        resp               0804A271  Unknown               Unknown
Unknown
          
         Amber8 Module: resp 
          
        forrtl: severe (24): end-of-file during read, unit 5, file
/home/rchaud/gaussian/ANTECHAMBER_RESP2.IN
        Image              PC        Routine                      Line
Source             
        resp               080A90B4  Unknown               Unknown
Unknown
        resp               080A7C8C  Unknown               Unknown
Unknown
        resp               0808705D  Unknown               Unknown
Unknown
        resp               0805CB50  Unknown               Unknown
Unknown 
        resp               0805D027  Unknown               Unknown
Unknown
        resp               0806B0BA  Unknown               Unknown
Unknown
        resp               0804A69B  Unknown               Unknown
Unknown
        resp               0804A4BA  Unknown               Unknown
Unknown 
        resp               0804A341  Unknown               Unknown
Unknown
        Unknown            00134E33  Unknown           Unknown  Unknown
        resp               0804A271  Unknown               Unknown
Unknown
        Cannot open charge file QOUT , exit 
         
        Both the resp1 and resp2.in files are empty.
        Our guess is that the gout(gaussian output file) has something
erroneous, on checking we found that the ESP fit runs past 9999 and this
might generate trouble!?      
              ESP Fit Center 9999 is at  -3.121005  2.016179 -4.380049
              ESP Fit Center **** is at  -3.482138  2.224679 -4.380049
              ESP Fit Center **** is at  -3.881619  2.344276 -4.380049
              ESP Fit Center **** is at  - 4.297913  2.368523 -4.380049
              ESP Fit Center **** is at  -5.881150  1.189846 -4.380049
...................
              .........................
         
         
        We are trying to use the step by step appraoch from start
instead of using antechamber to generate the prepin from the gout, but
is there any other way we can modfiy any input command such that the the
ESP fit runs more than the default 9999 cycles ?? 
        Any suggestions will be much appreciated.
         
        Thanks
         
        -Rima Chaudhuri
        Dept. of Bio. Engg.
        Bioinformatics Program - PhD candidate
        University of Illinois at Chicago
         
         
         
         
-----------------------------------------------------------------------
The AMBER Mail Reflector
To post, send mail to amber.scripps.edu
To unsubscribe, send "unsubscribe amber" to majordomo.scripps.edu
Received on Wed Jan 31 2007 - 06:07:30 PST